director 2/64 service manual

2–86 director 2/64 service manual
Diagnostics
22
Remove the loopback plug from the port receptacle. If directed by the customer,
connect a fiber-optic jumper cable attaching a device to the director.
If the port is operational and a device is not attached, both LEDs adjacent to the
port extinguish and the port state is No Light.
If the port is operational and a device is attached, the green LED illuminates, the
amber LED extinguishes, and the port state is Online.
Did removing the loopback plug solve the problem?
NO YES
The director is operational. Exit MAP.
Contact the next level of support. Exit MAP.
23
The WWN entered to configure port binding for this port is not valid or a nickname
was used that was not configured for the attached device in the Product Manager.
From the Hardware View, click Node List. Note the Port WWN column.
The Port WWN is the 8-byte (16-digit) world-wide name (WWN) assigned to the port
or Fibre Channel interface installed on the attached device.
If a nickname is not assigned to the WWN, the WWN is prefixed by the device
manufacturer’s name.
If a nickname is assigned to the WWN, the nickname displays in place of the
WWN.
The Bound WWN must be in the form of the raw WWN format
(xx:xx:xx:xx:xx:xx:xx:xx) or must be a valid nickname.
Did configuring the WWN or nickname solve the problem?
NO YES
The director is operational. Exit MAP.
Contact the next level of support. Exit MAP.