director 2/64 service manual

2–88 director 2/64 service manual
Diagnostics
NO YES
The director is operational. Exit MAP.
Contact the next level of support. Exit MAP.
27
Inspect and service the host bus adapters (HBAs), as necessary.
Did service of the HBAs solve the problem?
NO YES
Exit MAP.
Contact the next level of support. Exit MAP.
28
The director and attached device are performing a Fibre Channel link reset. This is a
transient state. Wait approximately 30 seconds and inspect port state and LED
behavior.
Did the link recover and resume operation?
NO YES
The Fibre Channel link and director are operational. Exit MAP.
Go to step 1.
29
A link incident message displayed in the Link Incident Log or in the Link Incident
field of the Port Properties dialog box; or an event code 581, 582, 583, 584, 585, or
586 was observed at the console of an OSI or FICON server attached to the director
reporting the problem.
Clear the link incident for the port.
1. At the Port Card View, right-click the port. A menu displays.
2. Choose Clear Link Incident Alert(s) option. The Clear Link Incident Alert(s)
dialog box displays (Figure 2–15).