director 2/64 service manual
director 2/64 service manual 2–91
Diagnostics
3. Monitor port operation for approximately five minutes.
Did the link incident recur?
YES NO
↓ The attached device, Fibre Channel link, and director are operational. Exit
MAP.
35
The director port reporting the problem is causing the recurrent link incident. The
recurring link incident indicates port or UPM card degradation and a possible pending
failure. Go to step 6.
36
A UPM card is not recognized by director firmware because the firmware version is
not supported or the UPM card failed. Advise the customer of the problem and
determine the correct firmware version to download from the HAFM server.
Download the firmware (Download a Firmware Version to a Director on page 3–52).
Perform the data collection procedure after the download.
Continue.
37
Did the firmware download solve the problem?
NO YES
↓ The director is operational. Exit MAP.
A UPM card failure is indicated. Go to step 7.
38
Is the Embedded Web Server interface operational?
NO YES
↓ Go to step 41.