director 2/64 service manual

director 2/64 service manual 2–93
Diagnostics
NO YES
A UPM card failure is indicated. Go to step 7.
42
Inspect Fibre Channel port operational states at the Embedded Web Server interface.
1. At the View panel, click the Port Properties tab. The View panel (Port
Properties tab) displays with port 0 highlighted in red.
2. Click the port number (0 through 63) for which a failure is suspected to display
properties for that port.
3. Inspect the Operational State field. Scroll down the View panel as necessary.
4. Table 2–13 lists port operational states and associated MAP 0600 steps that
describe fault isolation procedures.
43
Install a SFP optical transceiver in the port receptacle (RRP: SFP Optical Transceiver
on page 4–13).
1. This procedure is concurrent and can be performed while director power is on.
2. Verify location of the uninstalled port transceiver.
Figure 2–16 shows UPM card numbers (0 through15) and port numbers (00
through 63) for an OSI environment.
Table 2–13: MAP 600: Port Operational States and Actions
Operational
State Action
Offline Go to step 16.
Not Operational Go to step 16.
Port Failure Go to step 6.
Testing Internal or external loopback test in
process. Exit MAP.
Invalid
Attachment
Go to step 18.
Link Reset Go to step 28.
Not Installed Go to step 43.