director 2/64 service manual

director 2/64 service manual 2–95
Diagnostics
MAP 0700: Fabric, ISL, and Segmented Port Problem
Determination
This MAP describes isolation of fabric logout, interswitch link (ISL), and E_Port
segmentation problems. Failure indicators include:
An event code recorded at the Director 2/64 Event Log or the Embedded Web
Server event log.
A segmentation reason associated with a Fibre Channel port at the Embedded Web
Server interface.
A yellow triangle (attention indicator) displays over a UPM card graphic or at the
alert panel of the Products View, Hardware View, or Port Card View.
A link incident message recorded in the Link Incident Log or Port Properties
dialog box.
1
Was an event code 010, 011, 020, 021, 050, 051, 052, 060, 061, 062, 063, 070, 071, or
072 observed at the Director 2/64 Event Log (HAFM server) or at the Embedded Web
Server event log?
YES NO
Go to step 3.
2
Table 2–14 lists event codes, brief explanations of the codes, and associated steps that
describe fault isolation procedures.
Table 2–14: MAP 700: Event Codes
Event
Code Explanation Action
010 Login server unable to synchronize
databases.
Go to step 7.
011 Login server database invalid. Go to step 7.
020 Name server unable to synchronize
databases.
Go to step 7.
021 Name server database invalid. Go to step 7.