director 2/64 service manual
2–96 director 2/64 service manual
Diagnostics
3
Is fault isolation being performed at the HAFM server?
YES NO
↓ Fault isolation is being performed through the Embedded Web Server
interface. Go to step 22.
4
Does a yellow triangle (attention indicator) display over a UPM card graphic at the
Hardware View or display adjacent to a Fibre Channel port graphic at the Port Card
View?
YES NO
↓ The problem is transient and the director-to-fabric element connection is
operational. Exit MAP.
050 Management server unable to
synchronize databases.
Go to step 8.
051 Management server database invalid. Go to step 8.
052 Management server internal error. Go to step 8.
060 Fabric controller unable to synchronize
databases.
Go to step 9.
061 Fabric controller database invalid. Go to step 9.
062 Maximum interswitch hop count
exceeded.
Go to step 10.
063 Received link state record too large. Go to step 11.
070 E_Port is segmented. Go to step 12.
071 Director is isolated. Go to step 12.
072 E_Port connected to unsupported switch. Go to step 13.
Table 2–14: MAP 700: Event Codes (Continued)
Event
Code Explanation Action