director 2/64 service manual

director 2/64 service manual 2–97
Diagnostics
5
Inspect the port state and LED status for all ports with an attention indicator.
1. At the Port Card View, double-click the port graphic with the attention indicator.
The Port Properties dialog box displays as shown on the following page.
2. Inspect the Operational State field at the Port Properties dialog box.
Does the Operational State field indicate Segmented E_Port?
YES NO
Analysis for a UPM card failure or other link incident is not described in this
MAP. Go to MAP 0600: UPM Card Failure and Link Incident Analysis on
page 2–76. Exit MAP.
6
Inspect the Segmentation Reason field at the Port Properties dialog box. Table 2–15
lists port segmentation reasons and associated steps that describe fault isolation
procedures.
7
A minor error occurred that caused fabric services databases to be reinitialized to an
empty state. As a result, a disruptive fabric logout and login occurred for all attached
devices. The following list explains the errors.
Event code 010-Following a CTP2 card reset, the login server attempted to
acquire a fabric server database copy from the other CTP2 card and failed.
Table 2–15: MAP 700: Segmentation Reasons and Actions
Segmentation Reason Action
Incompatible operating parameters. Go to step 14.
Duplicate domain IDs. Go to step 15.
Incompatible zoning configurations. Go to step 16.
Build fabric protocol error. Go to step 17.
No principal switch. Go to step 19.
No response from attached switch. Go to step 20.
ELP retransmission failure timeout. Go to step 21.