director 2/64 service manual
2–98 director 2/64 service manual
Diagnostics
• Event code 011-Following a CTP2 card failover, the login server database failed
cyclic redundancy check (CRC) validation.
• Event code 020-Following a CTP2 card reset, the name server attempted to
acquire a fabric server database copy from the other CTP2 card and failed.
• Event code 021-Following CTP2 card failover, the name server database CRC
validation.
All attached devices resume operation after fabric login. Perform the data collection
procedure and return the Zip disk to HP for analysis by third-level support personnel.
Exit MAP.
8
A minor error occurred that caused management server databases to be reinitialized to
an empty state. As a result, a disruptive server logout and login occurred for all
attached devices. The following list explains the errors.
• Event code 050-Following CTP2 card reset, the management server attempted to
acquire a database copy from the other CTP2 card and failed.
• Event code 051-Following CTP2 card failover, the management server database
CRC validation.
• Event code 052-An internal operating error was detected by the management
server subsystem.
All attached devices resume operation after management server login. Perform the
data collection procedure and return the Zip disk to HP for analysis by third-level
support personnel. Exit MAP.
9
A minor error occurred that caused fabric controller databases to be reinitialized to an
empty state. As a result, the director briefly lost interswitch link capability. The
following list explains the errors.
• Event code 060-Following CTP2 card reset, the fabric controller attempted to
acquire a database copy from the other CTP2 card and failed.
• Event code 061-Following CTP2 card failover, the fabric controller database
failed CRC validation.
All interswitch links resume operation after CTP2 card reset or failover. Perform the
data collection procedure and return the Zip disk to HP for analysis by third-level
support personnel. Exit MAP.