director 2/64 service manual

2–100 director 2/64 service manual
Diagnostics
A 071 event code indicates the director is isolated from all directors in a multiswitch
fabric, and is accompanied by a 070 event code for each segmented E_Port. The 071
event code is resolved when all 070 events are corrected.
Obtain supplementary event data for each 070 event code.
1. At the HAFM server’s Hardware View, select Event Log from the Logs menu.
The Event Log displays.
2. Examine the first five bytes (0 through 4) of event data.
3. Byte 0 specifies the director port number (00 through 63) of the segmented
E_port. Byte 4 specifies the segmentation reason (Table 2–16).
13
As indicated by an event code 072, a director E_Port is connected to an unsupported
switch or fabric element.
Advise the customer of the problem and disconnect the interswitch link to the
unsupported switch. Exit MAP.
Table 2–16: MAP 700: Byte 4, Segmentation Reasons
Byte
4 Segmentation Reason Action
01 Incompatible operating
parameters.
Go to step 14.
02 Duplicate domain IDs. Go to step 15.
03 Incompatible zoning
configurations.
Go to step 16.
04 Build fabric protocol error. Go to step 17.
05 No principal switch. Go to step 19.
06 No response from attached
switch.
Go to step 20.
07 ELP retransmission failure
timeout.
Go to step 21.