5. Set the director online (Set Online State on page 3–43).
Did the switch priority change solve the problem and did both directors join through
the ISL to form a fabric?
NO YES
↓ The directors, associated ISL, and multiswitch fabric are operational. Exit
MAP.
Contact the next level of support. Exit MAP.
20
A director E_Port segmented (at an operational director) because a response to a
verification check indicates an attached director is not operational.
1. Perform the data collection procedure at the operational director and return the
Zip disk to HP for analysis by third-level support personnel.
2. Go to MAP 0000: Start MAP on page 2–12 and perform fault isolation for the
failed director.
Exit MAP.
21
A director E_Port segmented because the director was unable to receive a response
(from an operational fabric element) to multiple exchange link protocol (ELP) frame
transmissions, and unable to receive a fabric login (FLOGI) frame. The director’s
inability to receive responses is caused by a hardware or link failure. Port
segmentation occurs after five ELP transmissions, and prevents the failed director
from joining an operational Fibre Channel fabric.
The director exhibits other failure symptoms and one or more other failure event codes
are recorded in addition to the 070 event code (E_Port is segmented). Go to MAP
0000: Start MAP on page 2–12 and perform fault isolation for the failed director.
Exit MAP.
22
Is the Embedded Web Server interface operational?