director 2/64 service manual

director 2/64 service manual 3–7
Repair Information
To open the Director 2/64 Event Log from the Product Manager application, click
Logs and choose Event Log. The log contains the following columns:
Date/Time–The date and time the director event occurred.
Event–The three-digit event code associated with the event. See Appendix B,
Event Code Tables for an explanation of event codes.
Description–A brief description of the event.
Severity–The severity of the event (Informational, Minor, Major, or Severe).
FRU-Position–An acronym representing the FRU type, followed by a number
representing the FRU chassis position. FRU acronyms are:
BKPLNE–Backplane.
CTP–Control processor (CTP2) card.
SBAR–Serial crossbar (SBAR) card.
UPM (or GSF)–Universal port module (UPM) card.
PM–Port module (designation before a port module is identified as an FPM or
UPM type)
FAN–Fan module.
PWR–Power supply.
The chassis (slot) position for a nonredundant FRU is 0. The chassis positions for
redundant FRUs are 0 and 1. The chassis positions for UPM cards are 0 through
15 inclusive.
Event Data–Up to 32 bytes of supplementary event data (if available for the
event) in hexadecimal format. See Appendix B, Event Code Tables for an
explanation of the supplementary event data.
Refresh the Director 2/64 Event Log
To ensure recently-created events display in the Director 2/64 Event Log, periodically
refresh the log display. This is particularly important when inspecting the log for
informational event codes to verify a repair procedure. To refresh the log, click
Refresh at the bottom of the log window.