director 2/64 service manual
3–8 director 2/64 service manual
Repair Information
Clear the Director 2/64 Event Log
To ensure the Director 2/64 Event Log is up-to-date and not filled with archived
events, periodically clear the log display. To clear the log, click Clear at the bottom of
the log window.
Hardware Log
The Hardware Log as shown in Figure 3–4, displays a history of FRU removals and
replacements (insertions) for the director. The information is useful to maintenance
personnel for fault isolation and repair verification.
Figure 3–4: Hardware Log
To open the Hardware Log from the Product Manager application, click Logs and
select Hardware Log. The log contains the following columns:
• Date/Time–The date and time the FRU was inserted or removed.
• FRU–An acronym representing the FRU type. FRU acronyms are:
— BKPLNE–Backplane.
— CTP–CTP2 card.
— SBAR–SBAR card.
— UPM (or GSF)–UPM card.
— PM–Port module
— FAN–Fan module.
— PWR–Power supply.