director 2/64 service manual

director 2/64 service manual 3–9
Repair Information
Position–A number representing the FRU chassis position. The chassis (slot)
position for a nonredundant FRU is 0. The chassis positions for redundant FRUs
are 0 and 1. The chassis positions for UPM cards are 0 through 15 inclusive.
Action–The action performed (Inserted or Removed).
Part Number–The part number of the inserted or removed FRU.
Serial Number–The serial number of the inserted or removed FRU.
Link Incident Log
The Link Incident Log as shown in Figure 3–5, displays a history of Fibre Channel
link incidents (with associated port numbers) for the director. The information is
useful to maintenance personnel for isolating port problems (particularly expansion
port (E_Port) segmentation problems) and repair verification.
Figure 3–5: Link Incident Log
To open the Link Incident Log from the Product Manager application, click Logs
and choose Link Incident Log. The log contains the following columns:
Date/Time–The date and time the link incident occurred.
Port–The port number (0 through 63 inclusive) that reported the link incident.
Link Incident–A brief description of the link incident. Problem descriptions
include:
Implicit incident.
Bit-error threshold exceeded.