director 2/64 service manual
3–26 director 2/64 service manual
Repair Information
Segmented E_Port Messages:
— Incompatible operating parameters, such as resource allocation time-out
values (R_A_TOV) or error-detect time-out values (E_D_TOV), are
inconsistent. Refer to the hp StorageWorks director 2/64 installation guide for
more information.
— Duplicate domain IDs. Refer to the hp StorageWorks director 2/64 installation
guide for more information.
— Incompatible zoning configurations. See MAP 0700: Fabric, ISL, and
Segmented Port Problem Determination on page 2–95 for details.
05 External loopback
adapter connected to
the port.
A loopback plug is connected to the port and there is no
diagnostic test running.
06 N_Port connection
not allowed on this
port.
The port type configuration does not match the actual
port use. Port is configured as an E_Port, but attaches to
a node device.
07 Non-homogeneous
switch at other end of
the ISL.
The cable is connected to a non-homogeneous switch
and interop mode is set to homogeneous fabric mode.
08 ISL connection not
allowed on this port.
This port type configuration does not match the actual
port use (the port is configured as an F_Port, but
attaches to a switch or director).
10 Port binding
violation -
unauthorized WWN.
The WWN entered to configure port binding is not valid or
a nickname was used that is not configured through the
Product Manager for the attached device.
11 Unresponsive node
connected to port.
Possible causes are:
• Hardware problem on switch or on a connected
node where ELP frames are not delivered, the
response is not received, or a fabric login in
(FLOGI) cannot be received. There may be
problems in switch SBAR.
• Faulty or dirty cable connection.
• Faulty host bus adapters that do not send out
FLOGI within reasonable time frame.
Table 3–3: Invalid Attachment Messages and Explanations (Continued)