director 2/64 service manual

director 2/64 service manual 3–27
Repair Information
Build fabric protocol error.
No principal switch (no switch in fabric is capable of being principal switch).
No response from an attached switch.
Threshold Alert–If a threshold alert exists for the port, an alert indicator (yellow
triangle) displays by the Threshold Alert field, and the configured name for the
last alert received displays in the field.
Right-click a port connector to access a menu to:
•Open the Port Properties, Node Properties, or Port Technology dialog boxes.
Block or unblock the port.
Enable or disable port beaconing.
Perform port diagnostics.
Enable or disable port channel wrapping. This menu option displays only when
the director is configured for S/390 operating mode.
Swap one Fibre Channel port address with another. This menu option displays
only when the director is configured for S/390 operating mode.
Clear link incident alerts.
Reset the port.
Configure port binding.
Clear threshold alerts.
Performance View
The Performance View as shown in Figure 3–14, displays statistical information about
the performance of ports. The information is useful to maintenance personnel for
isolating port problems. To open the Performance View from the Hardware View,
choose the Performance tab.