director 2/64 service manual
director 2/64 service manual 3–49
Repair Information
Figure 3–28: Firmware Library dialog box
4. The firmware version displays at the lower left corner of the dialog box in
XX.YY.ZZ format, where XX is the version level, YY is the release level, and ZZ
is the patch level.
5. Click Close to return to the Hardware View.
Add a Firmware Version
The firmware version shipped with the director is provided on the hp StorageWorks
director 2/64 documentation kit CD. Subsequent firmware versions to upgrade the
director are provided to customers through the HP website.
NOTE: When adding a firmware version, follow procedural information in Release Notes that
accompany the firmware version. This information supplements information provided in this
general procedure.
To add a director firmware version to the library stored on the HAFM server hard
drive:
1. Obtain the new firmware version from the HP website:
NOTE: The following path is subject to change.
a. At the HAFM server or other personal computer (PC) with Internet access,
open the HP website. The uniform resource locator (URL) is:
http://thenew.hp.com/country/us/eng/support.html
NOTE: If required, obtain the customer-specific member name and password from the
customer or next level of support.
b. Follow links to HAFM software.
c. Click the Director 2/64 Firmware Version XX.YY.ZZ entry, where
XX.YY.ZZ is the desired version. The Windows 2000 Save As dialog box
displays.