director 2/64 service manual
director 2/64 service manual 4–9
FRU Removal and Replacement
16. Clear the amber system error LED on the director bezel:
a. At the Hardware View, right-click the front panel bezel graphic (away from a
FRU) to open a menu.
b. Click Clear System Error Light.
RRP: UPM Card
Use the following procedures to remove or replace a UPM card. A list of tools required
is provided.
Tools Required
The following tools are required to perform these procedures.
• ESD grounding cable and wrist strap.
• Torque tool and hex adapter (provided with the director).
• Fiber-optic protective plugs (provided with the director).
• Protective caps (provided with fiber-optic jumper cables).
• Fiber-optic cleaning kit.
Removing a UPM Card
To remove a UPM card:
1. Notify the customer that all ports on the defective UPM card will be blocked.
Ensure the customer’s system administrator quiesces Fibre Channel frame traffic
through any operational ports on the card and sets attached devices offline.
2. If the director is installed in a stand-alone configuration, go to step 3. If the
director is rack-mounted, unlock and open the cabinet front door as directed by the
customer representative.
3. Follow ESD procedures by attaching a wrist strap to the director chassis and your
wrist, as shown in Figure 4–1.
CAUTION: To avoid causing machine errors or damage while working on the director,
follow ESD procedures by connecting a grounding cable to the director chassis and
wearing an ESD wrist strap.