director 2/64 service manual
director 2/64 service manual 4–13
FRU Removal and Replacement
11. Restore communication to the replacement UPM card and set the card online as
directed by the customer (Unblock a UPM Card on page 3–47). Inform the
customer the UPM card is available for use.
12. Perform the data collection procedure (Collecting Maintenance Data on page
3–37).
13. Clear the amber system error LED on the director bezel:
a. At the Hardware View, right-click the front panel bezel graphic (away from a
FRU) to open a menu.
b. Click Clear System Error Light.
RRP: SFP Optical Transceiver
Use the following procedures to remove or replace an SFP optical transceiver from a
UPM card. A list of tools required is provided.
Tools Required
The following tools are required to perform these procedures.
• Fiber-optic protective plug (provided with the director).
• Protective cap (provided with the fiber-optic jumper cable).
• Fiber-optic cleaning kit.
Removing an SFP Optical Transceiver
To remove an SFP optical transceiver:
1. Notify the customer that the port with the defective transceiver will be blocked.
Ensure the customer’s system administrator sets the attached device offline.
2. If the director is installed in a stand-alone configuration, go to step 3. If the
director is rack-mounted, unlock and open the cabinet front door as directed by the
customer representative.
3. Identify the defective port transceiver from the amber LED on the UPM card or
failure information at the HAFM server’s Port Card View.
4. Block communication to the port (Block a Port on page 3–45).