director 2/64 service manual
4–26 director 2/64 service manual
FRU Removal and Replacement
12. Perform the data collection procedure (Collecting Maintenance Data on page
3–37).
13. Clear the amber system error LED on the director bezel:
a. At the Hardware View, right-click the front panel bezel graphic (away from a
FRU) to open a menu.
b. Click Clear System Error Light.
RRP: Power Module Assembly
Use the following procedures to remove or replace the power module assembly. A list
of tools required is provided.
Tools Required
The following tools are required to perform these procedures.
• Standard flat-tip screwdriver.
• Standard cross-tip (Phillips) screwdriver.
• ESD grounding cable and wrist strap.
Removing a Power Module Assembly
To remove the power module assembly:
1. Notify the customer the director will be powered off. Ensure the customer’s
system administrator quiesces Fibre Channel frame traffic through the director
and sets attached devices offline.
2. If the director is installed in a stand-alone configuration, go to step 3. If the
director is rack-mounted, unlock and open the cabinet front and rear doors as
directed by the customer representative.
3. Power off and unplug the director (Power-Off Procedure on page 3–41).
WARNING: Ensure both power cords are disconnected from the power module
assembly prior to removal or replacement.
4. Follow ESD procedures by attaching a wrist strap to an approved bench grounding
point and your wrist.