director 2/64 service manual

Product Manager
error < error number
5001 or 5002 >.
At the Configure
Operating
Parameters dialog
box, the R_A_TOV
entry must be greater
than E_D_TOV entry.
Verify and change one of the
entries to make the
relationship valid.
Product Manager
instance is currently
open.
A Product Manager
window is open.
Informational message only.
Send firmware failed. A firmware download
operation failed.
Retry the firmware download
operation. If the problem
persists, contact the next
level of support.
SNMP trap address
not defined.
If an SNMP
community name is
defined, a
corresponding SNMP
trap recipient address
must also be defined.
Enter a corresponding SNMP
trap recipient address.
Start diagnostics
failed. The test is
currently running.
Diagnostics for the
port was already
started from the Port
Diagnostics dialog
box
Informational message.
Stop diagnostics
failed. The test is
already running.
Diagnostics for the
port was not running
and the Stop was
selected on the Port
Diagnostics dialog
box. Diagnostics quit
for the port, but Stop
button remains
enabled.
Verify port operation. Retry
diagnostics for port and
choose Stop from the dialog
box. If problem persists,
contact your service
representative.
System diagnostics
cannot run. The
Operational Status is
invalid.
System diagnostics
cannot run on
directors or switches
with failed ports.
Replace failed ports.
Table A–2: Product Manager Messages (Continued)
Message Description Action