director 2/64 service manual
director 2/64 service manual B–9
Event Code Tables
Event Code: 062
Message: Maximum interswitch hop count exceeded.
Severity: Informational.
Explanation: The fabric controller software detected that a path to another fabric element (director or
switch) traverses more than seven interswitch links (ISLs or hops). This may result in
Fibre Channel frames persisting in the fabric longer than standard timeout values allow.
Action: If possible, reconfigure the fabric so the path between any two directors or switches
traverses no more than
seven ISLs.
Event Data: Byte 0 = domain ID of the fabric element (director or switch) more than seven hops
away.
Bytes 1 - 3 = reserved.
Distribution: Director HAFM Server Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔
Event Code: 063
Message: Remote switch has too many ISLs.
Severity: Major.
Explanation: The fabric element (director or switch) whose domain ID is indicated in the event data
has too many ISLs attached, and that element is unreachable from this director. HAFM
application Version 3.2 and earlier supports up to 32 ISLs. HAFM application Version 3.3
and later supports up to 128 ISLs.
Action: Reduce the ISLs on the indicated fabric element to a number within the limits specified.
Event Data: Byte 0 = domain ID of the fabric element (director or switch) with too many ISLs.
Bytes 1 - 3 = reserved.
Distribution: Director HAFM Server Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔