Event Code Tables
Event Code: 202
Message: Power supply thermal failure.
Severity: Major.
Explanation: The thermal sensor associated with a power supply indicates an overheat condition that
shut down the power supply. The second power supply assumes the full operating load
for the director.
Action: Replace the failed power supply. Perform the data collection procedure and return the
Zip disk and failed power supply to HP support personnel.
Event Data: No supplementary data included with this event.
Distribution: Director HAFM Server Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔
Event Code: 203
Message: Power supply AC voltage recovery.
Severity: Informational.
Explanation: AC voltage recovered for the power supply. Both power supplies adjust to share
operating load for the director.
Action: No action required.
Event Data: No supplementary data included with the event.