director 2/64 service manual

director 2/64 service manual B–21
Event Code Tables
Event Code: 207
Message: Power supply installed.
Severity: Informational.
Explanation: A redundant power supply was installed with the director powered on and operational.
Both power supplies adjust to share operating load for the director.
Action: No action required.
Event Data: No supplementary data included with the event.
Distribution: Director HAFM Server Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔
Event Code: 208
Message: Power supply false shutdown.
Severity: Major.
Explanation: Director operational firmware nearly shut down the indicated power supply as a result of
failure or facility power loss or voltage fluctuation.
Action: Confirm operation of facility power. If subsequent power loss events occur, replace the
failed power supply. Perform the data collection procedure and return the Zip disk and
failed power supply to HP support personnel.
Event Data: No supplementary data included with this event.
Distribution: Director HAFM Server Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔