director 2/64 service manual
director 2/64 service manual B–29
Event Code Tables
CTP2 Card Events (400 through 499)
Event Code: 400
Message: Power-up diagnostics failure.
Severity: Major.
Explanation: Power-on self tests (POSTs) detected a faulty field-replaceable unit (FRU) as indicated
by the event data.
Action: Replace the failed FRU with a functional FRU. Perform the data collection procedure and
return the Zip disk and faulty FRU to HP support personnel.
Event Data: Byte 0 = FRU code as follows: 01 = backplane, 02 = CTP2 card, 03 = SBAR assembly,
05 = fan module,
06 = power supply, and 08 through 0F = UPM cards.
Byte 1 = FRU slot number.
Distribution: Director HAFM Server Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔