director 2/64 service manual

B–30 director 2/64 service manual
Event Code Tables
Event Code: 410
Message: CTP card reset.
Severity: Informational.
Explanation: The indicated CTP2 card reset after a director power-on, CTP2 card installation,
hardware IML (CTP2 card faceplate), or software IPL. An IPL can be user-initiated at the
Product Manager application, or occur automatically after a firmware fault (event code
411). The event data indicates the type of reset.
Action: No action required.
Event Data: Byte 0 = reset type as follows: 00 = power-on hot-insert, 02 = IML, 04 = IPL,
08 = reset by other CTP2 card, 40 = partition switch, or 80 = dual CTP2 card hot-insert.
Distribution: Director HAFM Server Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔
Event Code: 411
Message: Firmware fault.
Severity: Major.
Explanation: Firmware executing on the indicated CTP2 card encountered an unexpected operating
condition and dumped the operating state to FLASH memory for retrieval and analysis.
The dump file is automatically transferred from the director to the HAFM server, where it
is stored for retrieval through the data collection procedure.
A non-disruptive failover to the backup CTP2 card occurs. When the dump and
subsequent IPL complete, the faulty CTP2 card reinitializes to become a the backup.
Action: Perform the data collection procedure and return the Zip disk to HP support personnel.
Event Data: Bytes 0 through 3 = fault identifier, least significant byte first.
Distribution: Director HAFM Server Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔