director 2/64 service manual

director 2/64 service manual B–41
Event Code Tables
Event Code: 450
Message: Serial number mismatch detected.
Severity: Informational
Explanation: This event occurs when the sequence number or OEM serial number in the system VPD
(read from the backplane) does not match the sequence number and serial Number that
was saved in NVRAM the last time the switch was IPLed. This event will occur normally
when a CTP2 is moved from one switch to the master position of another switch. This
event may occur abnormally when a hardware problem is causing a problem reading the
system VPD from the backplane.
Action: None. Any configured feature keys will be cleared, configuration information will be
synched with the backplane VPD, and the CTP2 will automatically be IPLed.
Event Data: Bytes 0-12 are the sequence number from the system VPD.
Bytes 13-31 are the OEM serial number obtained from the system VPD.
Distribution: Director HAFM Server Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔