director 2/64 service manual
B–42 director 2/64 service manual
Event Code Tables
Event Code: 451
Message: Switch speed incompatibility detected.
Severity: Informational
Explanation: The event occurs when the configured switch speed saved in NVRAM conflicts with the
speed capability of the switch. This event may occur when backup CTP2 hardware
running an early version of software (below 1.3) is improperly synchronized with a CTP2
operating at greater than 1Gb/s.
Action: None. Switch speed configuration and port speed configuration data will be set to a level
that is compatible with the CTP2 and the CTP2 will automatically be IPLed.
Event Data: None
Distribution: Director HAFM Server Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔
Event Code: 452
Message: Backup CTP incompatible with configured systems settings.
Severity: Informational
Explanation: This event occurs when the backup CTP2 is failed as a result of being incompatible with
current system settings. Normally this event will be generated following a hot-plug or
power on reset. (This event usually occurs when a CTP2 is installed into a system
operating at a switch speed not supported by the CTP2). This event should be followed
by a 414 event.
Action: Replace the backup CTP2 with a version of hardware capable of supporting the
user-configured settings or adjust the user settings to be compatible with the backup
CTP2 and reseat the backup CTP2.
Event Data: None
Distribution: Director HAFM Server Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔