Event Code Tables
Event Code: 502
Message: UPM card anomaly detected.
Severity: Informational.
Explanation: The CTP2 card detected a deviation in the normal operating mode or status of the
indicated four-port UPM card.
Action: No action required. An event code 504 is generated if the UPM card fails.
Event Data: Byte 0 = UPM slot position (00 through 0F).
Byte 1 = engineering reason code.
Bytes 4 through 7 = elapsed millisecond tick count.
Bytes 8 and 9 = high-availability error callout #1
Bytes 10 and 11 = high-availability error callout #2.
Byte 12 = detecting port.
Byte 13 = connected port.
Byte 14 = participating SBAR assembly.
Bytes 16 and 17 = high-availability error callout #3.
Bytes 18 and 19 = high-availability error callout #4.
Distribution: Director HAFM Server Host