director 2/64 service manual

B–46 director 2/64 service manual
Event Code Tables
Event Code: 503
Message: UPM card hot-removal completed.
Severity: Informational.
Explanation: An UPM card was removed with the director powered on and operational.
Action: No action required.
Event Data: Byte 0 = UPM slot position (00 through 0F).
Bytes 4 through 7 = elapsed millisecond tick count.
Distribution: Director HAFM Server Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔
Event Code: 504
Message: UPM card failure.
Severity: Major.
Explanation: The indicated UPM card failed.
Action: Replace the indicated UPM card with a functional UPM card of the same type. Perform
the data collection procedure and return the Zip disk and faulty card to HP support
personnel.
Event Data: Byte 0 = UPM slot position (00 through 0F).
Byte 1 = engineering reason code.
Bytes 4 through 7 = elapsed millisecond tick count.
Bytes 8 through 11 = reason code specific data.
Distribution: Director HAFM Server Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔