director 2/64 service manual
director 2/64 service manual B–51
Event Code Tables
Event Code: 510
Message: SFP optical transceiver hot-insertion initiated.
Severity: Informational.
Explanation: Installation of a small form factor pluggable (SFP) optical transceiver was initiated with
the director powered on and operational. The event indicates that operational firmware
detected the presence of the transceiver.
Action: No action required.
Event Data: Byte 0 = port number (00 through 63).
Bytes 4 through 7 = elapsed millisecond tick count.
Distribution: Director HAFM Server Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔
Event Code: 512
Message: SFP optical transceiver nonfatal error.
Severity: Minor.
Explanation: Director firmware detected a SFP optical transceiver non-fatal error.
Action: Replace the failed transceiver with a functional transceiver of the same type.
Event Data: Byte 0 = port number (00 through 63).
Byte 1 = engineering reason code.
Bytes 4 through 7 = elapsed millisecond tick count.
Distribution: Director HAFM Server Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔