director 2/64 service manual
B–52 director 2/64 service manual
Event Code Tables
Event Code: 513
Message: SFP optical transceiver hot-removal completed.
Severity: Informational.
Explanation: A SFP optical transceiver was removed while the director was powered on and
operational.
Action: No action required.
Event Data: Byte 0 = port number (00 through 63).
Bytes 4 through 7 = elapsed millisecond tick count.
Distribution: Director HAFM Server Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔
Event Code: 514
Message: SFP optical transceiver failure.
Severity: Major.
Explanation: A SFP optical transceiver in an UPM card failed. The amber LED corresponding to the
port illuminates to indicate the failure. Other ports remain operational if their LEDs are
extinguished.
Action: Replace the failed transceiver with a functional transceiver of the same type.
Event Data: Byte 0 = port number (00 through 63).
Byte 1 = engineering reason code.
Bytes 4 through 7 = elapsed millisecond tick count.
Distribution: Director HAFM Server Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔