director 2/64 service manual
B–56 director 2/64 service manual
Event Code Tables
SBAR Assembly Events (600 through 699)
Event Code: 600
Message: SBAR assembly hot-insertion initiated.
Severity: Informational
Explanation: Installation of a backup SBAR was initiated with the director powered on and
operational. The event indicates that operational firmware detected the presence of the
SBAR, but the SBAR is not seated. When the SBAR is seated in the director chassis
and identified by firmware, an event code 601 is generated.
Action: If event code 601 follows this event and the amber LED on the SBAR assembly
extinguishes, the replacement SBAR assembly is installed and no additional action is
required. If event code 601 does not follow this event, re-seat the SBAR assembly. If
event code 601 still does not display, replace the SBAR assembly.
Event Data: Byte 0 = SBAR slot position (00 or 01).
Bytes 4 through 7 = elapsed millisecond tick count.
Distribution: Director HAFM Server Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔
Event Code: 601
Message: SBAR assembly recognized.
Severity: Informational.
Explanation: An SBAR assembly is installed and recognized by director operational firmware.
Action: No action required.
Event Data: Byte 0 = SBAR slot position (00 or 01).
Bytes 4 through 7 = elapsed millisecond tick count.
Distribution: Director HAFM Server Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔