director 2/64 service manual
B–58 director 2/64 service manual
Event Code Tables
Event Code: 603
Message: SBAR assembly hot-removal completed.
Severity: Informational.
Explanation: An SBAR assembly was removed with the director powered on and operational.
Action: No action required.
Event Data: Byte 0 = SBAR slot position (00 or 01).
Bytes 4 through 7 = elapsed millisecond tick count.
Distribution: Director HAFM Server Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔
Event Code: 604
Message: SBAR assembly failure.
Severity: Major.
Explanation: The indicated SBAR assembly failed. If the active SBAR assembly fails, the backup
SBAR takes over operation. If the backup SBAR assembly fails, the active SBAR is not
impacted.
Action: Replace the failed SBAR assembly with a functional assembly. Perform the data
collection procedure and return the Zip disk and faulty assembly to HP support
personnel.
Event Data: Byte 0 = SBAR slot position (00 or 01).
Byte 1 = engineering failure reason code.
Bytes 4 through 7 = elapsed millisecond tick count.
Bytes 8 through 11 = event code specific data.
Distribution: Director HAFM Server Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔