director 2/64 service manual
director 2/64 service manual B–61
Event Code Tables
Thermal Events (800 through 899)
Event Code: 800
Message: High temperature warning (UPM card thermal sensor).
Severity: Major.
Explanation: The thermal sensor associated with an UPM card indicates the warm temperature
threshold was reached or exceeded.
Action: Replace the indicated UPM card with a functional UPM card of the same type. Perform
the data collection procedure and return the Zip disk and faulty card to HP support
personnel.
Event Data: No supplementary data included with this event.
Distribution: Director HAFM Server Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔
Event Code: 801
Message: Critically hot temperature warning (UPM card thermal sensor).
Severity: Major.
Explanation: The thermal sensor associated with an UPM card indicates the hot temperature
threshold was reached or exceeded.
Action: Replace the indicated UPM card with a functional UPM card of the same type. Perform
the data collection procedure and return the Zip disk and faulty card to HP support
personnel.
Event Data: No supplementary data included with this event.
Distribution: Director HAFM Server Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔