director 2/64 service manual

B–62 director 2/64 service manual
Event Code Tables
Event Code: 802
Message: UPM card shutdown due to thermal violation.
Severity: Major.
Explanation: An UPM card failed and was powered off because of excessive heat. This event follows
an indication that the hot temperature threshold was reached or exceeded (event code
801).
Action: Replace the failed UPM card with a functional UPM card of the same type. Perform the
data collection procedure and return the Zip disk and faulty card to HP support
personnel.
Event Data: No supplementary data included with this event.
Distribution: Director HAFM Server Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔
Event Code: 805
Message: High temperature warning (SBAR assembly thermal sensor).
Severity: Major.
Explanation: The thermal sensor associated with an SBAR assembly indicates the warm temperature
threshold was reached or exceeded.
Action: Replace the indicated SBAR assembly with a functional assembly. Perform the data
collection procedure and return the Zip disk and faulty assembly to HP support
personnel.
Event Data: No supplementary data included with this event.
Distribution: Director HAFM Server Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔