director 2/64 service manual

director 2/64 service manual B–63
Event Code Tables
Event Code: 806
Message: Critically hot temperature warning (SBAR assembly thermal sensor).
Severity: Major.
Explanation: The thermal sensor associated with an SBAR assembly indicates the hot temperature
threshold was reached or exceeded.
Action: Replace the indicated SBAR assembly with a functional assembly. Perform the data
collection procedure and return the Zip disk and faulty assembly to HP support
personnel.
Event Data: No supplementary data included with this event.
Distribution: Director HAFM Server Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔
Event Code: 807
Message: SBAR assembly shutdown due to thermal violation.
Severity: Major.
Explanation: An SBAR assembly failed and was powered off because of excessive heat. This event
follows an indication that the hot temperature threshold was reached or exceeded (event
code 806). If the active SBAR assembly fails, the backup SBAR takes over operation. If
the backup SBAR assembly fails, the active SBAR is not impacted.
Action: Replace the failed SBAR assembly with a functional assembly. Perform the data
collection procedure and return the Zip disk and faulty assembly to HP support
personnel.
Event Data: No supplementary data included with this event.
Distribution: Director HAFM Server Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔