director 2/64 service manual

B–64 director 2/64 service manual
Event Code Tables
Event Code: 810
Message: High temperature warning (CTP card thermal sensor).
Severity: Major.
Explanation: The thermal sensor associated with a CTP2 card indicates the warm temperature
threshold was reached or exceeded.
Action: Replace the indicated CTP2 card with a functional card. Perform the data collection
procedure and return the Zip disk and faulty card to HP support personnel.
Event Data: No supplementary data included with this event.
Distribution: Director HAFM Server Host
EWS
Event
Log
System
Error
Indicator
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔
Event Code: 811
Message: Critically hot temperature warning (CTP card thermal sensor).
Severity: Major.
Explanation: The thermal sensor associated with a CTP2 card indicates the hot temperature
threshold was reached or exceeded.
Action: Replace the indicated CTP2 card with a functional card. Perform the data collection
procedure and return the Zip disk and faulty card to HP support personnel.
Event Data: No supplementary data included with this event.
Distribution: Director HAFM Server Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔