director 2/64 service manual
2
Diagnostics
This chapter describes diagnostic procedures used by service representatives to fault
isolate the Director 2/64 problems or failures to the field-replaceable unit (FRU) level.
The chapter describes how to perform the maintenance analysis procedures (MAPs).
Maintenance Analysis Procedures
NOTE: HAFM and Product Manager screens in this manual may not match the screens on your
server and workstation. The title bars have been removed and the fields may contain data that
does not match the data seen on your system.
Fault isolation and related service procedures are provided through MAPs. The
procedures vary depending on the diagnostic information provided. MAPs consist of
step-by-step procedures that prompt service personnel for information or describe a
specific action to be performed. MAPs provide information to interpret system events,
isolate a director failure to a single FRU, remove and replace the failed FRU, and
verify director operation.
Factory Defaults
Table 2–1 lists the defaults for the passwords, and IP, subnet, and gateway addresses.
Table 2–1: Factory-set Defaults
Item Default
Customer password password
Maintenance password level-2
IP address 10.1.1.10
Subnet mask 255.0.0.0
Gateway address 0.0.0.0