director 2/64 service manual
120 Error while processing system
management command.
If this event persists, perform
data collection procedure
(Collecting Maintenance Data
on page 3–37) and return Zip
disk to HP support personnel.
121 Zone set activation failed -
zone set too large.
Reduce size of zone set and
retry.
200 Power supply AC voltage
failure.
Go to MAP 0100: Power
Distribution Analysis.
201 Power supply DC voltage
failure.
Go to MAP 0100: Power
Distribution Analysis.
202 Power supply thermal failure. Go to MAP 0100: Power
Distribution Analysis.
203 Power supply AC voltage
recovery.
No action required.
204 Power supply DC voltage
recovery.
No action required.
206 Power supply removed. Replace FRU.
207 Power supply installed. No action required.
208 Power supply false shutdown. Go to MAP 0100: Power
Distribution Analysis.
300 Cooling fan propeller failed. Go to MAP 0500: FRU Failure
Analysis
301 Cooling fan propeller failed. Go to MAP 0500: FRU Failure
Analysis.
302 Cooling fan propeller failed. Go to MAP 0500: FRU Failure
Analysis.
303 Cooling fan propeller failed. Go to MAP 0500: FRU Failure
Analysis.
304 Cooling fan propeller failed. Go to MAP 0500: FRU Failure
Analysis.
305 Cooling fan propeller failed. Go to MAP 0500: FRU Failure
Analysis.
Table 2–3: Event Codes Versus Maintenance Action (Continued)
Event
Code Explanation Action