director 2/64 service manual
2–8 director 2/64 service manual
Diagnostics
452 Backup CTP2 incompatible
with configured system
settings.
Replace the backup CTP2 with
a version of hardware capable
of supporting the
user-configured settings, or
adjust the user settings to be
compatible with the backup
CTP2, and reseat the backup
CTP2.
453 New feature key installed. No action required.
460 Management request out of
range.
The director found request data
from the management tool
(typically the HAFM
application) to be larger or
smaller than expected. The
connection to the management
tool will be temporarily lost.
After the link is reestablished,
verify that all information
changed in the managing tool
is within the specified ranges.
For example, verify that the
zones and zone members in a
zone set fall within the limits
stated in the user manual. Try
sending the request again.
500 UPM card hot-insertion
initiated.
No action required.
501 UPM card recognized. No action required.
502 UPM card anomaly detected. No action required.
503 UPM card hot-removal
completed.
No action required.
504 UPM card failure. Go to MAP 0600: UPM Card
Failure and Link Incident
Analysis.
Table 2–3: Event Codes Versus Maintenance Action (Continued)
Event
Code Explanation Action