director 2/64 service manual
director 2/64 service manual 2–17
Diagnostics
Redundant FRU failures are indicated. Go to step 23 to obtain event codes. If no event
codes are found, go to MAP 0500: FRU Failure Analysis on page 2–68. Exit MAP.
14
Does a yellow triangle (attention indicator) display as the background to the icon
representing the director reporting the problem?
YES NO
↓ Go to step 18.
15
Double-click the icon representing the director reporting the problem. The Hardware
View displays. At the Hardware View:
• Observe the Director 2/64 Status table is yellow and the director status is Minor
Failure or Redundant Failure.
• Inspect FRUs for a blinking red and yellow diamond (failed FRU indicator) that
overlays the FRU graphic.
Does a blinking red and yellow diamond overlay a power supply graphic?
NO YES
↓ A power supply failure is indicated. Go to step 23 to obtain event codes. If no
event codes are found, go to MAP 0100: Power Distribution Analysis on page
2–34. Exit MAP.
16
Does a blinking red and yellow diamond overlay a UPM card graphic?
NO YES
↓ A UPM card failure is indicated. Go to step 23 to obtain event codes. If no
event codes are found, go to MAP 0600: UPM Card Failure and Link Incident
Analysis on page 2–76. Exit MAP.
17
A blinking red and yellow diamond overlays a control processor (CTP2) card, SBAR
assembly, or fan module graphic.