director 2/64 service manual

2–30 director 2/64 service manual
Diagnostics
2. Disable port beaconing:
a. At the View panel, choose Operations option at the left side of the panel. The
Operations panel opens with the Port Beaconing page displayed.
b. Click the Beaconing State check box for the port. The check mark disappears
from the box and port beaconing is disabled.
c. Return to the View panel (Port Properties tab).
Continue.
47
At the View panel, does the Operational State field display a Segmented message?
NO YES
Port segmentation is indicated. Go to step 52 to obtain event codes. If no event
codes are found, go to MAP 0700: Fabric, ISL, and Segmented Port Problem
Determination on page 2–95. Exit MAP.
48
At the View panel, does the Operational State field display a message indicating a
port problem?
NO YES
Go to step 52 to obtain event codes. If no event codes are found, go to MAP
0600: UPM Card Failure and Link Incident Analysis on page 2–76. Exit
MAP.
49
Repeat step 45 through step 48 for each remaining Fibre Channel port for which a
problem is suspected.
Is a problem indicated for any of the ports?
NO YES
Go to step 52 to obtain event codes. If no event codes are found, go to MAP
0600: UPM Card Failure and Link Incident Analysis on page 2–76. Exit
MAP.