director 2/64 service manual

director 2/64 service manual 2–35
Diagnostics
3
A redundant power supply is disconnected from facility power, not properly installed,
or has failed.
Verify the power supply is connected to facility power.
1. Ensure the AC power cord associated with the power supply (PS0 or PS1) is
connected to the rear of the director and a facility power receptacle. If not, connect
the cord as directed by the customer.
2. Ensure the associated facility circuit breaker is on. If not, ask the customer to set
the circuit breaker on.
3. Ensure the AC power cord is not damaged. If damaged, replace the cord.
Was a corrective action performed?
YES NO
Go to step 5.
4
Verify redundant power supply operation.
1. Inspect the power supply and ensure the green PWR OK LED illuminates and all
amber LEDs extinguish.
2. At the HAFM server’s Hardware View, observe the graphic representing the
power supply and ensure a failure symbol (blinking red and yellow diamond) does
not display.
Is a failure indicated?
YES NO
Table 2–4: MAP 100: Event Codes
Event Code Explanation Action
200 Power supply AC voltage failure. Go to step 3.
201 Power supply DC voltage failure. Go to step 7.
202 Power supply thermal failure. Go to step 7.
208 Power supply false shutdown. Go to step 8.