director 2/64 service manual

2–38 director 2/64 service manual
Diagnostics
YES NO
Fault isolation is being performed at the HAFM server or Embedded Web
Server interface. Go to step 21.
11
Verify the director is connected to facility power and is powered on.
1. Ensure AC power cords (PS0 and PS1) are connected to the rear of the director
and to facility power receptacles. If not, connect the cords as directed by the
customer.
2. Ensure associated facility circuit breakers are on. If not, ask the customer set the
circuit breakers on.
3. Ensure the AC power cords are not damaged. If damaged, replace the cords.
4. Ensure the power switch (circuit breaker) at the rear of the director is set to the
ON (up) position.
Continue.
12
Inspect the director for indications of being powered on, such as:
At the front bezel, an illuminated power LED (green) or system error LED
(amber).
An illuminated green LED on the active CTP2 card.
At least one green PWR OK LED illuminated on a power supply.
Audio emanations and airflow from cooling fans.
Is the director powered on?
YES NO
Go to step 14.
13
Does inspection of a power supply indicate a failure (green PWR OK LED
extinguished and one or more amber LEDs illuminated)?
NO YES