director 2/64 service manual
director 2/64 service manual 2–45
Diagnostics
3
Table 2–5 lists event codes, brief explanations of the codes, and the associated steps
that describe fault isolation procedures.
4
POST/IPL diagnostics detected a FRU failure as indicated by an event code 400 with
supplementary event data.
1. At the HAFM server’s Hardware View, click Logs and choose Event Log. The
Event Log displays.
2. Examine the first two bytes (0 and 1) of event data.
3. Byte 0 is a FRU code that indicates the failed component. Byte 1 is the slot
number of the failed FRU (00 for a nonredundant FRU, 00 or 01 for redundant
FRUs, and 00 through 15 for UPM cards.
Table 2–6 lists byte 0 FRU codes and associated steps that describe fault isolation
procedures.
Table 2–5: MAP 200: Event Codes
Event Code Explanation Action
400 Power-up diagnostic failure. Go to step 4.
411 Firmware fault. Go to step 11.
413 Backup CTP2 card POST
failure.
Go to step 12.
Table 2–6: Byte 0 FRU Codes
Byte 0 Failed FRU Action
01 Backplane. Go to step 5.
02 CTP2 card. Go to step 6.
03 SBAR assembly. Go to step 7.
05 Fan module. Go to step 8.
06 Power supply. Go to step 9.
08-0F UPM card. Go to step 10.