director 2/64 service manual

2–48 director 2/64 service manual
Diagnostics
Contact the next level of support. Exit MAP.
11
POST/IPL diagnostics detected a firmware failure (as indicated by an event code 411)
and performed an online dump. All Fibre Channel ports reset after the failure and
devices momentarily logout, login, and resume operation.
Perform the data collection procedure and return the information to HP for analysis by
third-level support personnel. Exit MAP.
12
The backup CTP2 card failed POST/IPL diagnostics (as indicated by an event code
413) and must be removed and replaced (RRP: Redundant CTP2 Card on page 4–5).
This procedure is concurrent and can be performed while director power is on.
Perform the data collection procedure as part of FRU removal and replacement.
Did CTP2 card replacement solve the problem?
NO YES
The director is operational. Exit MAP.
Contact the next level of support. Exit MAP.