embedded web server user guide

embedded web server user guide A–11
Error Messages
Error 91: E_Port Type
Configured
Ports are not allowed to be
configured as E_Ports in
S/390 mode.
Configure the port as
either a fport or gport
and re-submit the
command.
Error 92: Not Allowed
While Port Is Unblocked
The port must be blocked to
complete this request.
Block the port and
re-submit the command.
Error 93: Not Allowed
While FICON MS Is
Installed
This request cannot be
completed because FICON
Management Server is
installed.
This operation is not
supported. No action
necessary.
Error 94: Invalid
Feature Combination
The features requested
cannot be installed at the
same time on one Director
or Switch.
Contact your sales
representative.
Error 99: Preferred
Domain ID Cannot Be
Zero
This product cannot be
configured to have a
preferred domain ID equal
to zero (0).
Ensure that the ID is
expressed as an integer
in the range 1–31 and
re-submit.
Error 101: Command
Not Supported on This
Product
This product does not
support the requested
command.
Command not
supported. No action
necessary.
Error 102: Switch Not
Operational
The request cannot be
completed because the
switch is not operational.
Consult the
installation/service
manual and contact your
service representative.
Error 115: Invalid
Switch Speed
The request cannot be
completed because the
switch is not capable of
operating at the configured
speed.
Consult the
installation/service
manual to determine the
speed capabilities of your
product.
Error 116: Switch Not
Capable of 2 Gb/sec
The request cannot be
completed because the
switch is not capable of
operating at 2 Gbps.
Consult the
installation/service
manual to determine the
speed capabilities of your
product.
Message Description Action