embedded web server user guide

A–12 embedded web server user guide
Error Messages
Error 117: Port Speeds
Cannot be Set at
Higher Data Rate than
Switch Speed
This request cannot be
completed because the
requested port speed is
faster than the
currently-configured switch
speed.
The switch speed should
first be configured to
accommodate changes
in the configured port
speed. The ports can not
operate at a faster rate
than the switch, itself.
Update the switch speed
and re-submit the
request.
Error 118: Invalid Port
Speed
This request cannot be
completed because the
requested port speed is not
recognized for this product.
Port speeds may be set
to 1 Gbps or 2 Gbps.
Update the port speed
and re-submit the
request.
Error 119: Switch
Speed Not 2 Gb/sec
This request cannot be
completed because the
switch speed has not been
set to 2 Gbps.
The switch speed must
be set to 2 Gbps in order
to accommodate a port
speed of 2 Gbps. Update
the switch speed and
re-submit the request.
Error 134: Invalid
Membership List
Generic message to
indicate a problem in either
the switch binding or fabric
binding membership list.
Be sure that the
membership list
submitted does not
isolate a switch already
in the fabric. If this is not
the case, the user needs
to be aware of all fabric
security rules and make
sure that the list
submitted adheres
appropriately.
Message Description Action