FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide (AA-RSNGC-TE/958-000289-001, June 2003)

Installing and Configuring the Director 2/64
113Director 2/64 Installation Guide
Use these steps to fabric-attach the director and create an ISL:
1. Verify that the director is defined via HAFM. See “Enabling HAFM to
Manage the Director” on page 80.
2. Verify that the preferred domain ID for the director is unique and does not
conflict with the ID of another director or switch participating in the fabric.
To change the domain ID, see “Configure Fabric Parameters” on page 93.
3. Verify that the R_A_TOV and E_D_TOV values for the director are identical
to the values for all directors and edge switches participating in the fabric.
4. Route a multi-mode or single-mode fiber-optic cable (depending on the ISL
distance between directors) between customer-specified E_Ports of both
directors.
5. At the Products View page, click the Director 2/64 icon. The Hardware
View page for the selected director displays.
6. Click the UPM card graphic supporting the E_Port connection to open the
Port Card View page.
7. Click the E_Port connector to open the Port Properties dialog box, as shown
in Figure 55.
8. Verify that the Link Incident field displays None and the Segmentation
Reason field is blank or displays N/A. If an ISL segmentation or other
problem is indicated, consult the HP StorageWorks Director 2/64 Service
Manual to isolate the problem. If no problems are indicated, installation is
complete.