FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide (AA-RSNGC-TE/958-000289-001, June 2003)
Technical Specifications
139Director 2/64 Installation Guide
Power Requirements
Table 8 lists Director 2/64 power requirements.
Operating Tolerances
Table 9 lists heating and cooling specifications, shock and vibration tolerances,
acoustical noise, and inclination.
Table 8: Power Requirements
Specification Value
Input voltage 100 to 120 or 200 to 240 VAC
Input frequency 50/60 Hz
Table 9: Operating Tolerances
Specification Value
Heat dissipation 16 UPM cards (maximum): 490W (1,672 BTU/hr)
Cooling airflow
clearances
Right and left sides: 5.1 cm (2.0 in)
Front and rear: 7.6 cm (3.0 in)
Top and bottom: No clearance required
Shock and vibration
tolerance
60 Gs for 10 milliseconds without non-recoverable errors
Acoustical noise 6.9 Bels
Inclination 10° maximum